Data Search by General Subjects

Data Search on:

Cost Effective Measurement of Halogens and Metals Using a Sorbent Trap Approach by John Pavlish, Energy and Environmental Research Center (EERC) - Hot Topic Hour September 26, 2013

 

Revision Date:  9/26/2013

Tags:  221112 - Fossil Fuel 化石燃料, Energy & Environmental Research Center, Sorbent Trap, Toxic Metal, HCl, Cadmium, Selenium, MATS, Coal


HAP Metal Monitoring: Using the Xact Multi-Metals CEMS as an Alternative to Monitoring with a PM CEMS and a Mercury CEMS by Krag Petterson, Pall. Hot Topic Hour October 13, 2011.

Krag Petterson discussed the use of the Xact Multi Metals CEM as an alternative to monitoring with a PM CEM and a mercury CEM.

Revision Date:  10/13/2011

Tags:  221112 - Fossil Fuel 化石燃料, Pall Corporation, Continuous Emissions Monitor, Toxic Metal, Monitoring


Ability to Measure Mass PM Ammonia, SO3 and NOx - Webinar, Hot Topic Hour October 13, 2011

It is possible to accurately measure emissions at the levels required in the new rules but it will not be easy and will require experience and skill. This is the sense of the discussion in the Hot Topic Hour.

Revision Date:  10/13/2011

Tags:  221112 - Fossil Fuel 化石燃料, EES, Pall Corporation, Geosyntec, Mechanical Systems, Inc., Avogadro Environmental Corp., SICK MAIHAK, Avogadro Environmental Corp., Ammonia, Stack Testing, Continuous Emissions Monitor, Air Quality, Toxic Metal, NOx, SO3, Particulates, Monitoring, Monitoring


Zero Liquid Discharge Options for FGD Wastewater presented by Bill Shaw, Veolia Water Solutions & Technologies - Hot Topic Hour June 16, 2011.

William (Bill) A. Shaw, P.E. Senior Process Engineer at HPD, a Veolia Water Solutions Company, explained the CoLD™ Process which was developed to achieve zero liquid discharge for wastewater from wet FGD and IGCC 'grey water'. The salt separation energy requirement has been reduced by lowering the slurry temperature.

Revision Date:  6/16/2011

Tags:  221112 - Fossil Fuel 化石燃料, Veolia Water Solutions & Technologies, Wastewater Treatment System, Toxic Metal, Wastewater Treatment


Modular ABMet* Introduction presented by James (Jay) Harwood - GE - Hot Topic Hour June 16, 2011.

Jay Harwood, Commercial Leader for ABMet at the GE Power and Water office in Oakville, Ontario, presented GE's new modular Advanced Biological Metals removal system (ABMet). This is a proven, reliable process to remove elevated levels of selenium and nitrate found in wastewater streams. The new modular design has made it less costly and more compact.

Revision Date:  6/16/2011

Tags:  221112 - Fossil Fuel 化石燃料, GE, Wastewater Treatment System, Toxic Metal, Wastewater Treatment


Analysis of Wet FGD Wastewaters presented by Michelle Briscoe, Brooks Rand Labs - Hot Topic Hour June 16, 2011.

Michelle L. Briscoe, VP of Analytical Services at Brooks Rand Labs, observed that evaluating the effectiveness of specific FGD wastewater heavy metal removal methods requires the collection and analysis of samples for metals concentrations at each stage in the treatment process. Because of interferences, testing is showing metal concentrations which are much higher than actual. Brooks Rand Labs has developed methods to eliminate the interferences and provide accurate measurement.

Revision Date:  6/16/2011

Tags:  221112 - Fossil Fuel 化石燃料, Brooks Rand Labs, Testing, Toxic Metal, Wastewater Treatment


Wastewater Treatment Systems presented by Naomi Levy, Infilco Degremont - Hot Topic Hour June 16, 2011.

Naomi Levy of Infilco Degremont discussed the many wastewater treatment systems which the company has supplied to treat power plant wastewater. A large system for Conemaugh is now under construction. Biological treatment can be added to the physical/chemical equipment when it is necessary to remove large quantities of selenium.

Revision Date:  6/16/2011

Tags:  221112 - Fossil Fuel 化石燃料, Infilco Degremont, Wastewater Treatment System, Toxic Metal, Wastewater Treatment


Heavy Metal Separation from Flue Gas Scrub Water with TMT15® presented by Rudiger Peldszus, Evonik Degussa GmbH - Hot Topic Hour June 16, 2011.

Ruediger Peldszus, Senior Manager for Applied Technology Advanced Intermediates at Evonik Degussa GmbH, backed up his claim that TMT 15®   is a good choice for separating heavy metals from flue gas scrubber water by citing a large number of installations in coal-fired power plants and also waste incineration plants. When asked how the chemical impacted the gypsum quality, Ruediger explained that the resultant compound is very small and exits the top of the hydroclone and not with the gypsum through the bottom. TMT 15 can also prevent mercury re-emission from the scrubber but for this to be successful, the parameters must be carefully evaluated. One of the participants has a client who has been challenged to successfully use the TMT 15 to prevent re-emission

Revision Date:  6/16/2011

Tags:  221112 - Fossil Fuel 化石燃料, Evonik Degussa GmbH, Wastewater Treatment Chemical, Mercury, Toxic Metal, Wastewater Treatment


FGD Wastewater Treatment Webinar - Hot Topic Hour June 16, 2011

Speakers discussed their experience with developing, testing, designing and troubleshooting treatment technologies for FGD wastewater.

Revision Date:  6/16/2011

Tags:  221112 - Fossil Fuel 化石燃料, Brooks Rand Labs, GE Power & Water, Veolia Water Solutions & Technologies, Evonik Degussa GmbH, Infilco Degremont, Wastewater Treatment Chemical, Testing, Mercury, Toxic Metal, Wastewater Treatment