European Prescription for U.S. SCR
A European SCR consultant, well familiar with the experience of the many electric utility owners of high-dust SCR systems retrofitted in Europe in the 1980s, would be expected to prescribe the following special provisions for a typical high-sulfur, low-ash, United States coal-fired unit according to Bill Ellison and Helmut Weiler:
ˇ A catalyst with a low SO2-to-SO3 conversion rate, i.e., less than 0.4 percent
ˇ Ammonia injection upstream of the economizer
ˇ Alkali injection upstream of the air preheater
ˇ Enameled heating plates on the flue gas side of the air preheater extending up to 2/3 of the plate height
ˇ Protection against corrosion of the casing and rotor structure on the cold side of the air preheater
ˇ Adequate means for optimizing soot blowing action within the air preheater
ˇ Limiting of design ammonia-slip to no more than 2 ppm, particularly where SO3 generation was already a problem
ˇ Measuring daily the ammonia content of the flyash.