Title: Doosan Lentjes super critical 300 MW CFB for low grade coals

In cooperation with its parent company DHI and supported by Doosan Babcock, Doosan Lentjes has developed a reference design for a 300 MW class SC-CFB boiler utilizing low grade coal. The activities have been backed by CFD analysis and physical model testing. The proven pantleg design, an opposed arrangement of 2x2 cyclones and integrated FBHE’s are the main features of the combustor. The flue gas leaving the cyclones enters into a cross-over duct leading to the inlet of the convective pass. The convective pass accommodates most of the heating surfaces. Due to the elevated steam temperatures it has become necessary to arrange a pendent type superheater in the upper part of the combustor. Coal and limestone are fed on the circulated ash flow and enters via 2x4 ducts into the combustor. Flue gas, primary and secondary air system has been designed according to a 2x 60 % approach thus enabling part load operation in case of unavailability of one fan or one rotary air preheater.

Click Here For Complete Article Text

 

   Person Information
   Application Sequencing
 221112 - Fossil Fuel 化石燃料                
 221118 - Other Electric Power                
Company  Product  Process  Other  Subjects  Event  Event  Date  Location  Publication  Publication  Date Text  Descriptor
  • Doosan Lentjes

  • Boiler

 

 

 

 

 

 

  • Article