Title: Multi stage centrifugals replaced at City of Altamonte Springs, FL

• The City of Altamonte Springs Regional Water Reclamation Facility (RWRF) has a permitted design capacity of 12.5 million gallons per day (MGD) on an average annual daily flow (AADF) basis. The current AADF is approximately half of the permitted value and the facility maintains consistent compliance with regulatory agency permit requirements related to effluent quality. • takeaways • Older multistage centifugals replaced with more efficient selections • Either turbo or rotary blowers recommended for the process • Concerns about complexity of turning down volume with multi stage centrifugal • Install centralized aeration control system • Rotary blower with VFD recommended for aeration in sludge holding tank where load fluctuations offer potential for energy savings