Title: Ceramic Tile Lined Absorber Vessels - Electric Power May 10 - 12, 2011, Chicago, Illinois by John Winkler, Project Manager, Siemens Environmental Systems and Services

Over the past several years, a significant number of FGD systems have been placed in operation. At each site, absorber materials of construction have varied based on plant preferences and industry experience. A portion of absorber vessels were constructed of solids alloy material such as 6% moly stainless steel, alloy 255, alloy 2205, and 317 LMN. Other vessels were built out of carbon steel, lined with flakeglass or rubber. Also some FGD units were constructed of concrete that is lined with ceramic tile. This paper will examine several SESS installations that have utilized ceramic tile lined absorber vessels. The discussion will include design experience, general arrangement considerations, construction issues, and schedule limitations that must be considered with this absorber arrangement. In addition, internal inspection observation will be presented from several sites, including Dominion Chesterfield 6 , PPL Montour, PPL Brunner Island, and Constellation Brandon Shores.

Click Here For Complete Presentation Text

 

   Person Information
  •     Winkler, John  -  Siemens Environmental Systems & Services

   Application Sequencing
 221112 - Fossil Fuel 化石燃料  Coal-Fired 燃煤              
Company  Product  Process  Other  Subjects  Event  Event  Date  Location  Publication  Publication  Date Text  Descriptor
  • Siemens Environmental Systems & Services

  • FGD

 

  • Air Quality

  • Electric Power 2011

 

  • 5/10/2011

 

  • Chicago, IL USA

 

 

 

  • Presentation