Vokes Macrogen GT Duo employs a hydrophobic media that provides effective water removal while in a study of 2 x 250 gas turbines in 2012 also delivered particle filtration to G4 or M5 efficiencies. This means that separate coalescer and prefiltration stages are unnecessary and that the redundant filter phase can be removed. The F9 final filters downstream from the Macrogen GT Duo system ran for a greater number ofhours and had a slightly lower pressure drop (105 against 110 Pascal) over the trial period. This result is due to the fact that the Macrogen has not only reduced the pressure drop but, at the same time, has increased the efficiency of prefiltration (from G4 to M5) better protecting the final filter. Click Here For Complete Article Text
|
||||||||||||||||||