Moving from two to three stages has significantly increased system pressure drop but simultaneously reduced the quantity of dust reaching the turbine by approximately 98%, lowering the chance of engine damage – fouling, corrosion and erosion. To quantify this additional pressure drop, it is agreed within the power generation industry that an increase in pressure drop of 50 Pa causes a fall in efficiency of 0.1%. Quantifying the benefit is a balance between reduced fouling and increased pressure drop. The increased pressure drop can be estimated to restrict performance by approximately 0.4%, while cutting fouling provides a 1.2% improvement in output (empirical average). Therefore… Click Here For Complete Article Text
|
||||||||||||||||||